Next: X-PLOR Trajectory Files (.DCD,
Up: Output Files
Previous: Output Files
The EGO output file format is self-explanatory.
Energies are given in units of kcal/mol, temperatures in Kelvin,
and coordinates in Å. The energy is given as a total, and also
in its components.
An EGO file starts with two REMARK lines and the contents of the control
file followed by the line `[BEGINCOORD]'. The next line contains the
number of atoms, the integration step, the step of analysis output and the
integration time step in fs), which are separated by white spaces.
These data may
be relevant for utility programs to analyze or convert the following atomic
coordinates (x, y, z coordinates in Å).
Following the list of atomic coordinates is an energy output for each
integration step up to the next analysis step. Energy data is signaled by the line
`[BEGINENERGY]' followed by a line with two numbers specifying the number of
comment lines and the number of rows of one energy output statement.
The second comment line
informs about the meaning of the data in columns. Note that in EGO data
in columns
are separated by white space, that is, data rows are not given by any
fixed row position !
An example listing (taken from Section 2.6) is shown below:
REMARK Outputfile of EGO_VIII on C-Version
REMARK C by M. Eichinger, H. Grubmueller and H. Heller, 1988-1995
... contents of control file ...
[BEGINCOORD]
568 552001 1 1.000000
9.930929 9.504575 -4.091603
8.971659 8.787418 -5.255728
...
8.105743 8.477091 -6.756792
9.998736 9.040694 -7.383424
[BEGINENERGY]
2 15
[Clock]=seconds, [Temperature]=K, [Energies]=kcal/mol
IntStep Clock Temperature Total Kinetic Electrostatic VDW Bonded Angle ...
552001 0.3676 269.27 -1505.217 423.7917 -2009.109 -402.8278 109.4822 ...
...
Next: X-PLOR Trajectory Files (.DCD,
Up: Output Files
Previous: Output Files
Helmut Heller
2000-04-19